    Development of a low-cost monitoring system for open 3d printing

    Get PDF
    3D printers for Rapid Prototyping and Additive Manufacturing have been widely accepted by large and small-scale industries or by many hobbyists. Due to its nature of layer by layer addition of material, identifying defects between the layers can be a crucial strategy to determine the quality of a 3D printed product by carefully monitoring the layerwise process during part building. This kind of approach gives an advantage in the applications where 3D printing of products requires high customization without compromise on part quality. In this work, a low-cost camera is installed in an open 3D printer, and computer vision algorithms are used to implement an in-situ monitoring system. The defects can be evaluated by comparing the printed layer to the deposition path of the open ISO G-code. The G-code printing file is modified to introduce the image capture step after each layer. The value of the area of missing or exceeding material is returned to the user with the corresponding images. A decision can be made to abort the job in case of important defects to avoid unnecessary waste in material, time, and costs

    Experimental assessment of compensated distortion in selective laser melting of Ti6Al4V parts

    Get PDF
    Selective laser melting (SLM) is a well-established Additive Manufacturing technique for the fabrication of end-use metal components. Process reliability and maximum product quality are ensured by 20 years of technology development. Nevertheless, depending on the complexity of the part geometry and on the operator experience, different trials are often needed before getting a part first time right. To reduce the number of failed jobs, simulation software packages predict residual stresses and related distortions in SLM parts and propose a compensated geometry for the “right first time” production of the product. In this works, the simulation routines of Amphyon software by Additive Works are experimentally calibrated and validated for the fabrication of a reference geometry by means of an EOSINT M270 machine and Ti6Al4V powder. The calibration of Amphyon is performed using three cantilever specimens and the calibrated SLM simulation is then used to compute the compensated shape of the reference part. The validation of the compensated shape by comparison to the real part geometry shows that Amphyon routines have good prediction capability and dimensional accuracy

    Experimental testing of 3D printed polymeric heat exchangers

    Get PDF
    Unlike conventional manufacturing technologies, additive manufacturing and 3D printing empower engineers with much more design freedom. Heat exchangers with complex internal channels or lattice structures can be designed for layerwise manufacturing by maximizing the surface to volume ratio. Low-weight polymeric heat exchangers are employed in aviation and aerospace applications. For increasing the thermal performance of polymers, additives can be used such as graphene. In this study, a Grafylon filament is used for the production of a simple heat exchanger by 3D printing. The heat exchanger is composed of two external shells and an interior duct with a two-stage 45-degree bend. For watertight purposes, the duct is manufactured by selective laser sintering of polyamide powder. Two replicas of the shells are fabricated by 3D printing of Grafylon and acrylonitrile butadiene styrene (ABS) respectively. The thermal performance of the two materials is experimentally tested and compared also to numerical simulations. The results of the study show that the Grafylon filament provides enhanced thermal performance to 3D printed heat exchangers of polymeric material

    Benchmarking analysis of digital light processing resins in terms of dimensional accuracy and geometric tolerances

    Get PDF
    Additive Manufacturing (AM) is a groundbreaking fabrication technology that is revolutionizing traditional manufacturing processes. Generally, following a layer-by-layer approach, in AM the final shape of the product is built through the progressive deposition of one or more materials. The most common extrusion-based AM technique for thermoplastic polymers is Fused Filament Fabrication (FFF), whilst for photopolymer resins, Digital Light Processing (DLP) and Stereolithography (SLA) are widely used. In the last years, DLP has spread rapidly, due to its low average cost and simple use. Moreover, a lower layer thickness can be used in DLP if compared to the FFF process. Therefore, hobbyists or amateur end users and many companies use DLP to achieve high dimensional accuracy and smooth surfaces for small products. This work aims to evaluate the performance of three different DLP resins in terms of dimensional and geometrical accuracy. A benchmarking activity is carried out using a Rover printer by Sharebot to produce replicas of a reference part using Sharebot resins. After production, the replicas were inspected using a Coordinate Measuring Machine (CMM) for comparing the dimensional accuracy of the geometric features according to ISO IT grades and tolerances of the GD&T system. The results of this study are also compared with previous works from the literature in the conclusions

    An approach to evaluate the wear of customized manufacturing fixtures through the analysis of 3D scan data

    Get PDF
    With the recent gain in popularity and adoption of additive manufacturing in various industrial sectors, quality assessments to determine the functionality of 3D printed parts are critical. This holds especially when the parts are subjected to wear as in the case of the production of customized fixtures. Some reinforced polymeric materials for additive manufacturing can be employed as a substitute for low-resistance metals like Aluminium. In this paper, a custom-made tribometer was used to simulate the wear of 3D printed fixtures of Alumide material for sheet metal inspection operations. Contact 3D scanning is used to monitor the condition of the fixture for increasing numbers of wear cycles. This study aims to calculate the wear volume of cylindrical pins starting from the surface points of 3D scan data. The methodology employs alpha shapes to obtain the progression of the volume and area of the worn zone. Experimental tests to evaluate the wear volume were carried out to compare the durability of Alumide to that of Aluminium, filling the gap of previous literature, which had focused exclusively on diametral wear. The findings indicate a better wear resistance for Alumide specimens and this work contributes to broadening the knowledge about the wear behaviour and the lifetime of 3D printed parts

    Multiarticular chronic tophaceous gout with severe and multiple ulcerations: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Gout is a common inflammatory arthritis caused by articular precipitation of monosodium urate crystals. It usually affects the first metatarsophalangeal joint of the foot and less commonly other joints, such as wrists, elbows, knees and ankles.</p> <p>Case presentation</p> <p>We report the case of a 75-year-old Caucasian man with tophaceous multiarticular gout, soft-tissue involvement and ulcerated tophi on the first metatarsophalangeal joint of the left foot, on the first interphalangeal joint of the right foot and on the left thumb.</p> <p>Conclusion</p> <p>Ulcers due to tophaceous gout are currently uncommon considering the positive effect of pharmaceutical treatment in controlling hyperuricemia. Surgical treatment is seldom required for gout and is usually reserved for cases of recurrent attacks with deformities, severe pain, infection and joint destruction.</p

    Completeness of Reporting in Diet- and Nutrition-Related Randomized Controlled Trials and Systematic Reviews With Meta-Analysis:Protocol for 2 Independent Meta-Research Studies

    Get PDF
    Background: Journal articles describing randomized controlled trials (RCTs) and systematic reviews with meta-analysis of RCTs are not optimally reported and often miss crucial details. This poor reporting makes assessing these studies’ risk of bias or reproducing their results difficult. However, the reporting quality of diet- and nutrition-related RCTs and meta-analyses has not been explored. Objective: We aimed to assess the reporting completeness and identify the main reporting limitations of diet- and nutrition-related RCTs and meta-analyses of RCTs, estimate the frequency of reproducible research practices among these RCTs, and estimate the frequency of distorted presentation or spin among these meta-analyses. Methods: Two independent meta-research studies will be conducted using articles published in PubMed-indexed journals. The first will include a sample of diet- and nutrition-related RCTs; the second will include a sample of systematic reviews with meta-analysis of diet- and nutrition-related RCTs. A validated search strategy will be used to identify RCTs of nutritional interventions and an adapted strategy to identify meta-analyses in PubMed. We will search for RCTs and meta-analyses indexed in 1 calendar year and randomly select 100 RCTs (June 2021 to June 2022) and 100 meta-analyses (July 2021 to July 2022). Two reviewers will independently screen the titles and abstracts of records yielded by the searches, then read the full texts to confirm their eligibility. The general features of these published RCTs and meta-analyses will be extracted into a research electronic data capture database (REDCap; Vanderbilt University). The completeness of reporting of each RCT will be assessed using the items in the CONSORT (Consolidated Standards of Reporting Trials), its extensions, and the TIDieR (Template for Intervention Description and Replication) statements. Information about practices that promote research transparency and reproducibility, such as the publication of protocols and statistical analysis plans will be collected. There will be an assessment of the completeness of reporting of each meta-analysis using the items in the Preferred Reporting Items for Systematic reviews and Meta-Analysis (PRISMA) statement and collection of information about spin in the abstracts and full-texts. The results will be presented as descriptive statistics in diagrams or tables. These 2 meta-research studies are registered in the Open Science Framework. Results: The literature search for the first meta-research retrieved 20,030 records and 2182 were potentially eligible. The literature search for the second meta-research retrieved 10,918 records and 850 were potentially eligible. Among them, random samples of 100 RCTs and 100 meta-analyses were selected for data extraction. Data extraction is currently in progress, and completion is expected by the beginning of 2023. Conclusions: Our meta-research studies will summarize the main limitation on reporting completeness of nutrition- or diet-related RCTs and meta-analyses and provide comprehensive information regarding the particularities in the reporting of intervention studies in the nutrition field

    Protocol for a meta-research study of protocols for diet or nutrition-related trials published in indexed journals:general aspects of study design, rationale and reporting limitations

    Get PDF
    INTRODUCTION: The Standard Protocol Items: Recommendations for Interventional Trials (SPIRIT) reporting guideline establishes a minimum set of items to be reported in any randomised controlled trial (RCT) protocol. The Template for Intervention Description and Replication (TIDieR) reporting guideline was developed to improve the reporting of interventions in RCT protocols and results papers. Reporting completeness in protocols of diet or nutrition-related RCTs has not been systematically investigated. We aim to identify published protocols of diet or nutrition-related RCTs, assess their reporting completeness and identify the main reporting limitations remaining in this field. METHODS AND ANALYSIS: We will conduct a meta-research study of RCT protocols published in journals indexed in at least one of six selected databases between 2012 and 2022. We have run a search in PubMed, Embase, CINAHL, Web of Science, PsycINFO and Global Health using a search strategy designed to identify protocols of diet or nutrition-related RCTs. Two reviewers will independently screen the titles and abstracts of records yielded by the search in Rayyan. The full texts will then be read to confirm protocol eligibility. We will collect general study features (publication information, types of participants, interventions, comparators, outcomes and study design) of all eligible published protocols in this contemporary sample. We will assess reporting completeness in a randomly selected sample of them and identify their main reporting limitations. We will compare this subsample with the items in the SPIRIT and TIDieR statements. For all data collection, we will use data extraction forms in REDCap. This protocol is registered on the Open Science Framework (DOI: 10.17605/OSF.IO/YWEVS). ETHICS AND DISSEMINATION: This study will undertake a secondary analysis of published data and does not require ethical approval. The results will be disseminated through journals and conferences targeting stakeholders involved in nutrition research
    • …
    corecore